FRF Fast Reference Move To Reference Switch
Used in: Digital Input Signals (80), Motion in closed-loop operation (32), Reference move procedure (40), Reference
Description:
Starts a reference move to the reference point switch.
Long description
FRF sets the current position to the value of
. If the ref-
erence move was successful, absolute motion will then be possible
in closed-loop operation.
The motion can be stopped by
,
, and
Servo mode must be switched on for the specified axis (axes)
(closed-loop operation).
Use FNL or FPL to do a reference move for an axis that does not
have a reference point switch but instead, only limit switches.
Format:
FRF[{␣<AxisID>}]
Arguments:
<AxisID>
Axis ID
If multiple axes are specified in the command, they are moved syn-
chronously.
If not arguments are specified, all axes are moved synchronously.
Troubleshooting:
Illegal axis identifier
Servo mode not active (
responds with the value "0")
FRF? Get Referencing Result
Used in: Reference point definition options (40)
Description:
Queries whether the specified axis is referenced.
Format:
FRF?[{␣<AxisID>}]
Arguments:
<AxisID>
Axis ID
The value for all axes will be queried if no arguments are specified.
Response:
{AxisID>=<uint>
␊
}
<uint> Reference state of the axis (BOOL)
<uint>
Description
1
Axis referenced successfully
0
Axis not referenced
Troubleshooting:
Illegal axis identifier
9 COMMAND REFERENCE
PZ285EN
‒
1/30/2019
132