parameter value in the nonvolatile memory (
Startup Value
column), the line in the list
is highlighted in color.
7. Click
Load and Save Parameters > Save parameters to stage database...
.
8. The
Save Parameters as User Stage Type
dialog opens.
9. Save the changed parameter values as new positioner type in
Dialog Save Parameters as
User Stage Type
:
a) Leave the entry in the
Parameters of axis
field unchanged.
b) Enter the name for the new positioner type into the
Save as
field.
c) Click
OK
.
➔
The new positioner type was saved in the positioner database. The displayed positioner
type was updated in PIMikroMove. The new positioner type is also available immediately
for selection in the
Select connected stages
step.
Changing a Positioner's Parameter Set
1. Select the
E-871.1A1N > Select connected stages...
menu item in the main window of
PIMikroMove.
➔
The
Start up stages/axes for E-871.1A1N
window opens and the
Select connected stages
step is active.
2. Select a positioner type that you created during the
Select connected stages
as described
above:
a) Click
Assign Type from ID Chip
.
or
a) Highlight the positioner in the
Stage database entries
list.
b) Click
Assign
.
8 E-871.1A1N FUNCTIONS
PZ285EN
‒
1/30/2019
110
M O T I O N | P O S I T I O N I N G