The
Save all changes permanently?
dialog is opened.
2. If the
Select connected stages
step is displayed in the
Start up controller
window:
a) Select the appropriate positioner type: Click either
Assign Type from ID Chip
or mark
the matching positioner type in the
Stage database entries
list and click
Assign
.
b) Confirm selection with
OK
to load the parameter settings for the selected positioner
type from the positioner database into the E-871.1A1N.
➔
The
Save all changes permanently?
dialog is opened.
3. Specify how you want to load the parameter settings into the E-871.1A1N in the
Save all
changes permanently?
dialog box:
■
Temporary load: Click
Keep the changes temporarily
to load the parameter settings
into the volatile memory of the E-871.1A1N. The settings are lost when the E-871.1A1N
is switched off or rebooted.
■
Load as default values: Click
Save all settings permanently on controller
to load the
parameter settings into the nonvolatile memory of the E-871.1A1N. The settings are
available immediately after switching on or rebooting the E-871.1A1N and do not need
to be reloaded.
➔
The
Start up controller
window with the
Start up axes
step is displayed.
7 STARTUP / OPERATION
PZ285EN
‒
1/30/2019
60
M O T I O N | P O S I T I O N I N G