You have started initial
with PIMikroMove.
✓
If necessary, you have set the
.
✓
All devices are still ready for operation.
Checking the Servo Control Parameters: Recording the Step Response
1. Open the
Data Recorder
window in PIMikroMove via the
E-871.1A1N > Show data
recorder
menu item.
➔
The
Data Recorder
window is opened.
2. Make the following settings in the
Data Recorder
window:
a) If necessary, switch on servo mode by checking the
Servo
checkbox.
b) Set the number of data points to be read for the graphical display (max. 8192) in the
#
of data points
field.
c) Set the amplitude of the step to be performed to a value that is typical for your
application (specified as physical units).
d) Set the number of servo cycles to be recorded in the
Record Rate - # cycles
field.
3. Click the
Configure…
button to open the window for configuring the data recorder.
➔
The
Configure Data Recorder
window is opened.
4. Make sure that "Commanded Position of Axis" and "Actual Position of Axis" are selected
as variables to be recorded in the
Configure Data Recorder
window and click
OK
to close
the window.
7 STARTUP / OPERATION
PZ285EN
‒
1/30/2019
68
M O T I O N | P O S I T I O N I N G