SMO? Get Control Value
Description:
Returns last valid control value of the specified axis.
Format:
SMO?[{␣<AxisID>}]
Arguments:
<AxisID>
Axis ID
Response:
{<AxisID>=<float>
␊
}
<AxisID>
Axis ID
<float>
Control value, dimensionless
Troubleshooting:
Illegal axis identifier
SPA Set Volatile Memory Parameters
Used in: Parameter Commands (104)
Description:
Sets a parameter in the volatile memory to a specific value.
Long description
Up to four parameters can be set per command.
Wrong values can lead to faulty operation or damage to the hard-
ware.
Format:
SPA{␣<ItemID>␣<PamID>␣<PamValue>}
Arguments:
<ItemID>
Element of the electronics
<PamID>
Parameter ID
<PamValue>
Parameter value
Troubleshooting:
Impermissible element identifier
Wrong parameter ID
SPA? Get Volatile Memory Parameters
Used in: Parameter Commands (104), Saving Parameter Values in a Text File (105)
Description:
Queries the value of a parameter in the volatile memory.
Long description
Up to four parameters can be queried per command.
Format:
SPA?[{␣<ItemID>␣<PamID>}]
Arguments:
<ItemID>
Element of the electronics
<PamID>
Parameter ID
Response:
{<ItemID>
␣
<PamID>=<PamValue>
␊
}
<ItemID>
Element of the electronics
<PamID>
Parameter ID
<PamValue>
Parameter value
Troubleshooting:
Impermissible element identifier
Wrong parameter ID
9 COMMAND REFERENCE
PZ285EN
‒
1/30/2019
159