5. If you have selected a user-defined lookup table and want to fill the table with values:
a) Click the corresponding
Calibrate...
button to open the
Controller Joystick Calibration
window.
b) Move the HID's axes to all extreme positions. The custom lookup table values are
determined in this way.
c) Let go of the axis.
d) If you want to change the neutral area of the axis (i.e., the area around the center
position of the axis where no change in the controlled motion variable is triggered), set
the
Dead band
slider accordingly.
e) If the values in the user-defined lookup table are to describe a parabolic waveform,
click the
Parabolic curve
checkbox.
f) Click
OK
in the
Controller Joystick Calibration
window to copy the appropriate values
from the lookup table.
➔
The lookup table values are written to the E-871.1A1N's volatile memory. The writing
progress is indicated in a separate window. The window for the writing process and
the Controller Joystick Calibration window automatically close after the writing
process has finished.
6. Close the
Test and Calibrate HIDevice
window with
Close
.
7. Depending on what is next, do the following:
8 E-871.1A1N FUNCTIONS
PZ285EN
‒
1/30/2019
90
M O T I O N | P O S I T I O N I N G