Requirements
✓
You have installed the positioner in the same way as it will be used in your application
(corresponding load, orientation, and fastening).
✓
Initial motion
in PIMikroMove.
✓
All devices are still ready for operation.
Information
The settling behavior of the axis in closed-loop operation is influenced by the notch filter
settings.
►
Set the notch filter before you optimize the servo-control parameters.
Recording the step response
1. Open the
Data Recorder
window in PIMikroMove via the
E-871.1A1N > Show data
recorder
menu item.
➔
The
Data Recorder
window is opened.
2. Make the following settings in the
Data Recorder
window:
a) Use the
Servo
checkbox to make sure that servo mode is switched off: If the
Servo
checkbox is checked, uncheck to switch servo mode off.
b) Set the number of data points to be read for the graphical display (max. 8192) in the
#
of data points
field.
c) Set the amplitude of the step to be performed to a value that is typical for your
application (specified as physical units).
d) Set the number of servo cycles to be recorded in the
Record Rate - # cycles
field.
3. Click the
Configure…
button to open the window for configuring the data recorder.
➔
The
Configure Data Recorder
window is opened.
4. In the
Configure Data Recorder
window, make sure that the "Actual Position of Axis" is
selected as the variable to be recorded, and close the window with
OK
.
7 STARTUP / OPERATION
PZ285EN
‒
1/30/2019
63
M O T I O N | P O S I T I O N I N G