0x61 Invert Direction Of Motion For Joystick-Controlled Axis?
Used in: HID Control Configuration (86)
Description:
Inverts the direction of motion for HID-controlled axes.
Data type
INT
Command level
0
Item type
Axis
Source of data
Positioner database
Possible values
0 Direction of motion not inverted (default)
1 Direction of motion inverted
0x63 Distance Between Limit And Hard Stop (Phys. Unit)
Used in: Reference move procedure (40)
Description:
Gap between internal limit switch and hard stop.
Determines the maximum stopping distance during reference
moves. The actual velocities during a reference move are calculated
on the basis of this value, the set deceleration (0xC) and set veloci-
ties (0x49 and 0x50).
Data type
FLOAT
Command level
0
Item type
Axis
Source of data
Positioner database
10 PARAMETER REFERENCE
PZ285EN
‒
1/30/2019
191