0x32 Has No Limit Switches?
Used in: Limit Switch Detection (38), Using Digital Inputs as Source of the Limit Switch Signals (80)
Description:
Do the mechanics not have limit switches?
Activates motion stop at the installed limit switches.
Data type
INT
Command level
0
Item type
Axis
Source of data
Positioner database
Possible values
0 Mechanics have limit switches
1 Mechanics do not have limit switches
0x33 Motor Offset Positive
Description:
Drive offset for the positive direction of motion.
Data type
INT
Command level
0
Item type
Axis
Source of data
Positioner database
Possible values
0 to 32766
0x34 Motor Offset Negative
Description:
Drive offset for the negative direction of motion.
Data type
INT
Command level
0
Item type
Axis
Source of data
Positioner database
Possible values
0 to 32766
10 PARAMETER REFERENCE
PZ285EN
‒
1/30/2019
185
M O T I O N | P O S I T I O N I N G