STE Start Step And Response Measurement
Used in: Motion in closed-loop operation (32), Motion in open-loop operation (33), Starting the Recording (74)
Description:
Starts a step for the specified axis and records the step response.
Long description
Servo mode must be switched on for the specified axis (axes)
(closed-loop operation). HID control may not be activated for the
corresponding axis.
The target position must be inside the soft limits.
Format:
STE␣<AxisID>␣<Amplitude>
Arguments:
<AxisID>
Axis ID
<Amplitude>
Jump size in physical units
Troubleshooting:
Illegal axis identifier
Servo mode not active (
responds with the value "0")
Executing motion commands deactivated by parameter 0x130
Target position outside of the soft limits
HID control is enabled
STP Stop All Axes
Used in: (96), Triggering Motion (32)
Description:
Stops all axes abruptly.
Long description
Stops all motion started by motion commands (e.g.,
), reference point defi-
nition commands (FNL, FPL,
Also stops the macro.
Sets the error code to 10.
After the axes are stopped, their target positions are set to their cur-
rent positions.
Format:
STP
SVO Set Servo Mode
Used in: (26), Restoring the E-871.1A1N's Operational Readiness (73)
Description:
Sets the servo mode for the specified axis.
Long description
The target position is set to the current position when switching to
closed-loop operation. SVO deactivates the brake when it is activa-
ted.
Format:
SVO{␣<AxisID>␣<ServoState>}
Arguments:
<AxisID>
Axis ID
<ServoState>
Servo mode (UINT)
9 COMMAND REFERENCE
PZ285EN
‒
1/30/2019
162