Electrical connection
The pumps are equipped with a 10 000 AIC breaker.
Electrical shock may result in severe injury.
Always disconnect main power before servicing the pump.
All the internal electrical connections required for using the pump are
made prior to shipment.
However, the electrical connection of the main power supply is provided
by the user.
Customer electrical
installation protection
Main circuit breaker rating (recommended values).
200 - 230 V
Low Voltage
380 - 440 V
High Voltage
A103P
15 A
10 A
A603P / A1003P
30 A
20 A
Make sure that the main switch is off during electrical connection.
Study the preliminary precautions
B 00
.
Line voltage
Check that the line voltage corresponds to the pump label, voltage
located on the upper cover. See
B 01