GB 02891 - Edition 05 - Oct 13
3/6
C 42
Monitoring system function table
Selection
Choice
Defi nition
Initial confi guration
AUX TEMP.
ENABLED
DISABLED
NA
Disabled
BUZZER OPTION
ENABLED
DISABLED
Controls buzzer ON/OFF in case of a
fault. Buzzer stop by pressing
ENTER
.
Enabled
3 % 4
Selection
Selection
Setting limits
Initial confi guration
SERIAL LINK 1
TYPE
RS 232 / RS 485 / Network
RS 232
ECHO
ENABLED / DISABLED
Enabled
SPEED
9600 bauds
9600 bauds
PARITY
no / even / odd
No
2 STOP BITS
ENABLED / DISABLED
Disabled
ADDRESS
0 to 999
0
N
2
FLOW SENSOR
WARNING TIME
0 to 60 min
0
ALARM TIME
0 to 60 min / DISABLED
Disabled
PURGE WARNING
-
15 to 60 slm (standard liter per
minute)
15
INTERNAL T°
INPUT VALUE
70 to 110°C
100
ALARM THRESHOLD
+10°C above the set value
130
% . 4 % 2
% . 4 % 2
DEFINITION MENU
3 % 4
SETTING
% . 4 % 2
% . 4 % 2
adixen Vacuum Products - Operating instructions - A3P Series