GB 02868 - Edition 06 - Oct 13
1/6
A 40
Technical characteristics
Characteristics
Units
A103P
A603P
A1003P
Peak Pumping speed
(50/60Hz)
m
3
/h
cfm
l/mn
120/120
70/70
2000/2000
480/600
282/350
8000/10000
900/900
530/530
15000/15000
Typical ultimate pressure
(without N
2
purge) (50/60 Hz)
hPa
mtorr
6.5 10
-3
/6.5 10
-3
5/5
5 10
-4
/3 10
-4
4.10
-1
/2 10
-1
3 10
-4
/3 10
-4
2 10
-1
/2 10
-1
Typical ultimate pressure
(with 20 slm N
2
purge) (50/60 Hz)
hPa
mtorr
2.6 10
-2
/2.6 10
-2
20/20
2 10
-3
/1 10
-3
1.5 /7.5 10
-1
1 10
-3
/1 10
-3
7.5 10
-1
/7.5 10
-1
Max. continuous inlet flow
slm
50
25
Supply voltage
(1)(4)
Low voltage
High voltage
V
200/230V - 3 phases - 50/60Hz
380/440V - 3 phases - 50/60Hz
Power consumption at ultimate
pressure (without purge)
kW
1
1.3 to 1.6
Noise level
(2)
dbA
< 58
< 65
N
2
Flowrate range
slm
15 to 60
Ambient temperature
°C
5 to 40
Water flow
l/h
100 mini
Water temperature
°C
10 to 25
Gear box fluid capacity
(3)
oil type : A 113
cm
3
cc
100
100 (A103P)
+
700 (Roots)
Weight
lbs
Kg
275.6
125
595.2
270
Inlet flange
ISO-K
DN50
DN100
Exhaust flange
I S O -
KF
DN25
Secondary exhaust port
mm
Ø
50
adixen Vacuum Products - Operating instructions - A3P Series