GB 04155 - Edition 04 - Oct 13
7/8
D 30
Diagnosis and trouble shooting
INCIDENT
CAUSE
TROUBLESHOOTING
Hazard
D35 EMERGENCY STOP
Pump emergency stop is
engaged
Rotate to unlock the emergency
stop on the control panel of the
front panel.
Other problem
Call the customer service center.
Hazard
D36 ADP CONTACTOR
EMO plug disconnected
Connect the EMO plug
B 100
.
Check that there is a strap
between pins 2 and 3 of EMO
B 100
.
Other problem
Call the customer service center.
Hazard
D37 ROOTS BREAKER
Incorrect monitoring
configuration (for A103P)
Check that «SYSTEM SELECT»
on «DEFINITION MENU» is set
to «A3R0»
C 42
.
Roots breaker (RT2) in position
«0»
Set the Roots breaker in position
«
1
».
Other problem
Call the customer service center.
Hazard
D39 ROOTS CONTACTOR
Incorrect monitoring
configuration (for A103P)
Check that «SYSTEM SELECT»
on «DEFINITION MENU» is set
to «A3R0»
C 42
.
Other problem
Call the customer service center.