GB 02872 - Edition 03 - Oct 13
5/6
B 00
Safety instructions
Pump labels
Located on the upper cover, this label indicates that due to its heavy
weight, the product should not be handled manually, but always
through appropriate handling devices.
Located on the upper cover and at the rear of the pump, this label
warns the user against possible risk of injury due to any hand contact
with hot surfaces. It states that protective gloves should be used before
performing any intervention. The protective gloves should be used in
accordance to the protective gloves supplier’s instruction.
Located on the upper cover, this label indicates that some of the
internal parts are energized and could cause electrical shocks in case
of contact. It advises to disconnect the pump before any intervention
or to properly lock-out and tag-out the equipment breaker before any
intervention on the pump.
Located on the upper cover, this label informs the user, that moving parts
present inside the pump could cause personal injury, like crushing or
cutting. The user must keep all body parts away from moving parts.
Located on the upper cover, this label indicates that the internal
electrical circuit is energized when EMO is activated.
A 329 982 - 1
A 329 982 - 2 and A 215 138 - 2
A 329 982 - 3
A 329 982 - 4
adixen Vacuum Products - Operating instructions - A3P Series