2/6
A 40
GB 02868 - Edition 06 - Oct 13
Technical characteristics
(1)
According to CE regulations, A3-P Range pumps can withstand a transient supply voltage variation of ±10%.
(2)
The acoustic pressure is measured on a pump whose temperature has been stabilized. The pump is on a table one meter
from the ground. There are 5 microphones (4 arround the pump, 1 above) which are placed one meter from the ground
and one meter from the pump.
(3)
Oil charge is filled at factory. Do not modify the oil level. A 113 Material safety data sheet is available on request.
(4)
For Semi hardwire option, the Short Circuit Current Rate (SCCR) of the pump is rated of 5kA.
Characteristics
Units
A103P
A603P
A1003P
Environmental conditions:
Use of the product
Altitude
Ambient operating temperature
Maximum relative humidity
Transient overvoltage
Pollution degree
indoor use
up to 2000 m
5 to 40 °C (41 to 104 °F)
80 % for temp. up to 31 °C (87 °F)
decreasing linearly to 50 % at 40 °C (104 °F)
category II
rate 2
adixen Vacuum Products - Operating instructions - A3P Series