![Parker AC890PX Series Скачать руководство пользователя страница 73](http://html1.mh-extra.com/html/parker/ac890px-series/ac890px-series_product-manual_755704073.webp)
4-7
Safe Torque Off
AC890PX AC Drive
Safety Specification
As assessed to EN ISO13849-1 and EN61800-5-2 and certified by BGIA (a German trade association for
industrial safety) the 890 PX frames have the following related safety values:-
Criterion
Requirement
Value achieved
SIL3
For type A subsystems, HFT = 1:
SFF ≥ 60%
95%
SIL3
10
-7
≥ PFH ≥ 10
-8
3.8 x 10
-9
PLe
Category 3; PFH ≤ 4,29 x 10
-8
3.8 x 10
-9
PLe
30 years ≤ MTTFd ≤ 100 years
100 years
1
PLe
DC = medium
Medium
Mission Time
20 years
20 years
Note: all values quoted in this table are valid only when the two STO user inputs are driven independently.
This is as required by EN ISO 13849-1 category 3. See the Alignment to European Standards section in this
chapter for the required architecture which must be used throughout the machine design relevant to the
drive under consideration.
EMC Specification
In addition to the mandatory requirements of EN61800, the STO functionality has been subjected to testing
for immunity at higher levels. In particular it has been tested for radiated immunity up to 3GHz which
includes frequencies used by mobile telephones and walkie-talkies.
1
EN ISO13849 limits MTTFd to 100 years.
Содержание AC890PX Series
Страница 17: ...2 5 Product Overview AC890PX AC Drive 890PX bottom wire entry ...
Страница 25: ...3 4 Installing the Drive AC890PX AC Drive Outline Drawing of AC890PX 132kW 400kW HC471581 page 2 of 2 ...
Страница 144: ...The Keypad 7 9 AC890PX AC Drive The Menu System Map ...
Страница 145: ...7 10 The Keypad AC890PX AC Drive The Menu System Map continued ...
Страница 159: ...7 24 The Keypad AC890PX AC Drive Assembly Procedure Mounting Dimensions for the Remote Mounted 6901 Keypad ...
Страница 250: ...Programming D 10 AC890PX AC Drive VALUE INPUT BREAK VALUE INPUT LOSS LEVEL BREAK ENABLE BREAK TYPE UNPROCESSED ...
Страница 328: ...Programming D 88 AC890PX AC Drive Functional Description ...
Страница 386: ...Programming D 146 AC890PX AC Drive Setpoint Drive Frequency Frequency 1 Frequency 2 ...
Страница 391: ...D 151 Programming AC890PX AC Drive Speed Rated Speed No Load Speed synchronous speed Rated Torque Torque ...