Programming
D-150
AC890PX AC Drive
SLIP COMP
SETUP::MOTOR CONTROL::SLIP COMP
Designed for VOLTS/Hz motor Control Mode.
The slip compensation function block allows the Drive to maintain motor speed in the presence of load disturbances.
Parameter Descriptions
ENABLE
PREF: 23.01
Default: FALSE
Range: FALSE / TRUE
For the slip compensation to be operational this must be TRUE.
MOTORING LIMIT
PREF: 23.02
Default: 150.0 rpm
Range: 0.0 to 600.0 rpm
The maximum trim that will be produced by the slip compensation block when the motor is driving the load (motoring).
REGEN LIMIT
PREF: 23.03
Default: 150.0 rpm
Range: 0.0 to 600.0 rpm
The maximum trim that will be produced by the slip compensation block when the motor is being driven by the load,
(regenerating).
Functional Description
Based on the rated speed, the no load speed and the rated load of the motor, the slip compensation block adjusts the demand
frequency to compensate for any speed reduction resulting from the load.
Содержание AC890PX Series
Страница 17: ...2 5 Product Overview AC890PX AC Drive 890PX bottom wire entry ...
Страница 25: ...3 4 Installing the Drive AC890PX AC Drive Outline Drawing of AC890PX 132kW 400kW HC471581 page 2 of 2 ...
Страница 144: ...The Keypad 7 9 AC890PX AC Drive The Menu System Map ...
Страница 145: ...7 10 The Keypad AC890PX AC Drive The Menu System Map continued ...
Страница 159: ...7 24 The Keypad AC890PX AC Drive Assembly Procedure Mounting Dimensions for the Remote Mounted 6901 Keypad ...
Страница 250: ...Programming D 10 AC890PX AC Drive VALUE INPUT BREAK VALUE INPUT LOSS LEVEL BREAK ENABLE BREAK TYPE UNPROCESSED ...
Страница 328: ...Programming D 88 AC890PX AC Drive Functional Description ...
Страница 386: ...Programming D 146 AC890PX AC Drive Setpoint Drive Frequency Frequency 1 Frequency 2 ...
Страница 391: ...D 151 Programming AC890PX AC Drive Speed Rated Speed No Load Speed synchronous speed Rated Torque Torque ...