D-121
Programming
AC890PX AC Drive
Parameter Descriptions
ENCODER INVERT
PREF: 158.03
Default: FALSE
Range: FALSE/TRUE
This parameter is used to switch the direction of the input encoder, forward or reverse.
ENCODER TYPE
PREF: 158.04
Default: 3
Range: See below
This parameter defines the type of encoder being used.
Enumerated Value : Type
0 : QUADRATURE
single-ended pulse encoder
1 : CLOCK/DIR
single-ended pulse encoder
2 : CLOCK
single-ended pulse encoder
3 : QUADRATURE DIFF
differential pulse encoder
4 : CLOCK/DIR DIFF
differential pulse encoder
5 : CLOCK DIFF
differential pulse encoder
6 : SINCOS INC
sin/cos encoder
7 : ABS ENDAT ST
single turn endat absolute encoder
8 : ABS ENDAT MT
multi-turn endat absolute encoder
Note that if an absolute endat encoder is used, the encoder MUST be wired exactly as specified. If not, it will fail to calibrate
the absolute position and an error will result when the drive is started. This status can be viewed via the parameter
CALIBRATN STATUS.
* OUTPUT GBOX IN
PREF: 158.05
Default: 1
Range: 1 to
+2000000000
See OUTPUT GBOX OUT below.
Содержание AC890PX Series
Страница 17: ...2 5 Product Overview AC890PX AC Drive 890PX bottom wire entry ...
Страница 25: ...3 4 Installing the Drive AC890PX AC Drive Outline Drawing of AC890PX 132kW 400kW HC471581 page 2 of 2 ...
Страница 144: ...The Keypad 7 9 AC890PX AC Drive The Menu System Map ...
Страница 145: ...7 10 The Keypad AC890PX AC Drive The Menu System Map continued ...
Страница 159: ...7 24 The Keypad AC890PX AC Drive Assembly Procedure Mounting Dimensions for the Remote Mounted 6901 Keypad ...
Страница 250: ...Programming D 10 AC890PX AC Drive VALUE INPUT BREAK VALUE INPUT LOSS LEVEL BREAK ENABLE BREAK TYPE UNPROCESSED ...
Страница 328: ...Programming D 88 AC890PX AC Drive Functional Description ...
Страница 386: ...Programming D 146 AC890PX AC Drive Setpoint Drive Frequency Frequency 1 Frequency 2 ...
Страница 391: ...D 151 Programming AC890PX AC Drive Speed Rated Speed No Load Speed synchronous speed Rated Torque Torque ...