![Parker AC890PX Series Скачать руководство пользователя страница 307](http://html1.mh-extra.com/html/parker/ac890px-series/ac890px-series_product-manual_755704307.webp)
D-67
Programming
AC890PX AC Drive
INVERSE TIME PMAC
SETUP::MOTOR CONTROL::INVERSE TIME PMAC
Designed for PMAC control mode.
The purpose of the inverse time is to automatically reduce the drive current limit in response to prolonged overload
conditions for drive and motor protection.
As the drive current exceeds the
AIMING POINT
level, the excess current is integrated. Motor current is allowed to flow up
to
INVERSE TIME OP
for a period defined by the
DELAY
parameter. At this point the inverse time current limit is ramped
down to the
AIMING POINT
. The rate at which the current limit is ramped to the
AIMING POINT
is defined by
DOWN
TIME
.
Once the overload condition is removed, the inverse time current limit is ramped back to the normal
INVERSE TIME OP
at
a rate determined by the
UP TIME
.
Parameter Descriptions
AIMING POINT
PREF: 162.01
Default: 105.00 %
Range: 50.00 to 105.00%
Determines the final level of the inverse time current limit after a period of prolonged motor overload as a percentage of the
stack rated current.
DELAY
PREF: 162.02
Default: 4.0 s
Range: 0.5 to 60.0s
Overload duration before inverse time current limit action is taken. This value is based on INVERSE TIME OP under normal
conditions. Time is reduced to 25% of DELAY if the drive speed is lower than 2.5 (electrical) Hz.
DOWN TIME
PREF: 162.03
Default: 1.0 s
Range: 0.5 to 10.0s
Determines the rate at which the inverse time current limit is ramped to the AIMING POINT after a period of prolonged
overload.
Содержание AC890PX Series
Страница 17: ...2 5 Product Overview AC890PX AC Drive 890PX bottom wire entry ...
Страница 25: ...3 4 Installing the Drive AC890PX AC Drive Outline Drawing of AC890PX 132kW 400kW HC471581 page 2 of 2 ...
Страница 144: ...The Keypad 7 9 AC890PX AC Drive The Menu System Map ...
Страница 145: ...7 10 The Keypad AC890PX AC Drive The Menu System Map continued ...
Страница 159: ...7 24 The Keypad AC890PX AC Drive Assembly Procedure Mounting Dimensions for the Remote Mounted 6901 Keypad ...
Страница 250: ...Programming D 10 AC890PX AC Drive VALUE INPUT BREAK VALUE INPUT LOSS LEVEL BREAK ENABLE BREAK TYPE UNPROCESSED ...
Страница 328: ...Programming D 88 AC890PX AC Drive Functional Description ...
Страница 386: ...Programming D 146 AC890PX AC Drive Setpoint Drive Frequency Frequency 1 Frequency 2 ...
Страница 391: ...D 151 Programming AC890PX AC Drive Speed Rated Speed No Load Speed synchronous speed Rated Torque Torque ...