![Parker AC890PX Series Скачать руководство пользователя страница 139](http://html1.mh-extra.com/html/parker/ac890px-series/ac890px-series_product-manual_755704139.webp)
7-4
The Keypad
AC890PX AC Drive
Keys for Operating the Drive Locally
FORWARD/
REVERSE
Control - Changes the direction of motor rotation. Only operates when the drive is in Local
Speed Control mode.
JOG
JOG
Control - Runs the motor at a speed determined by the JOG SETPOINT parameter. When the
key is released, the drive returns to “stopped”. Only operates when the drive is “stopped“ and
in Local Start/Stop mode.
RUN
Control - Runs the motor at a speed determined by the LOCAL SETPOINT or REMOTE
SETPOINT parameter.
Trip Reset - Resets any trips and then runs the motor as above. Only operates when the drive
is in Local Start/Stop (Seq) mode.
STOP/RESET
Control - Stops the motor. Only operates when the drive is in Local Sequence mode.
Trip Reset - Resets any trips and clears displayed message if trip is no longer active.
The L/R Key
The
L/R
key (LOCAL/REMOTE) toggles between Remote and Local Mode. In doing so, the view of the SETPOINT
parameter in the OPERATOR menu toggles between SETPOINT (LOCAL) and SETPOINT (REMOTE). The default is for
the SETPOINT (REMOTE) parameter to be displayed.
NOTE
A different naming convention is applied in the OPERATOR menu for these parameters when displayed as the first
parameter entry:
REMOTE SETPOINT is displayed as SETPOINT (REMOTE)
LOCAL SETPOINT is displayed as SETPOINT (LOCAL)
COMMS SETPOINT is displayed as SETPOINT (COMMS)
JOG SETPOINT is displayed as SETPOINT (JOG)
Содержание AC890PX Series
Страница 17: ...2 5 Product Overview AC890PX AC Drive 890PX bottom wire entry ...
Страница 25: ...3 4 Installing the Drive AC890PX AC Drive Outline Drawing of AC890PX 132kW 400kW HC471581 page 2 of 2 ...
Страница 144: ...The Keypad 7 9 AC890PX AC Drive The Menu System Map ...
Страница 145: ...7 10 The Keypad AC890PX AC Drive The Menu System Map continued ...
Страница 159: ...7 24 The Keypad AC890PX AC Drive Assembly Procedure Mounting Dimensions for the Remote Mounted 6901 Keypad ...
Страница 250: ...Programming D 10 AC890PX AC Drive VALUE INPUT BREAK VALUE INPUT LOSS LEVEL BREAK ENABLE BREAK TYPE UNPROCESSED ...
Страница 328: ...Programming D 88 AC890PX AC Drive Functional Description ...
Страница 386: ...Programming D 146 AC890PX AC Drive Setpoint Drive Frequency Frequency 1 Frequency 2 ...
Страница 391: ...D 151 Programming AC890PX AC Drive Speed Rated Speed No Load Speed synchronous speed Rated Torque Torque ...