Programming
D-50
AC890PX AC Drive
FIREWIRE REF
SETUP:: PHASE CONTROL::FIREWIRE REF
Performance Level = ADVANCED : CLOSED-LOOP VEC Motor Control Mode only.
The FireWire option card (Option B) must be fitted to the drive.
This block processes Virtual Master commands received over Firewire communications, producing position, speed and
acceleration references to be used by the control loops, when Firewire is selected as the reference source (Firewire Comms Sel
is TRUE in Comms Control block).
Parameter Descriptions
CHANNEL
PREF: 119.01
Default: 0
Range: 0 to 62
This parameter sets the Firewire channel that the master reference is being received from.
RESET
PREF: 119.02
Default: FALSE
Range: FALSE / TRUE
This parameter resets the Outputs to zero. Note if this is set TRUE whilst the drive is running following the Firewire Reference,
then the drive will decelerate to zero speed on the System Ramp.
INVERT
PREF: 119.03
Default: FALSE
Range: FALSE / TRUE
This parameter inverts the master reference. Note that this inversion does not take place locally in the drive, so the master and
local diagnostics below will always be in the same direction.
GEAR RATIO A
PREF: 119.04
Default: 1000000
Range: -2000000000 to
2000000000
This parameter provides a Gear Ratio A/B (see GEAR RATIO B) inserted between master reference input and Firewire Ref
outputs. Output = Gear ratio A / Gear Ratio B * Master Input.
GEAR RATIO B
PREF: 119.05
Default: 1000000
Range: -2000000000 to
2000000000
This parameter provides a Gear Ratio A/B (see GEAR RATIO A) inserted between master reference input and Firewire Ref
outputs. Output = Gear ratio A / Gear Ratio B * Master Input.
Содержание AC890PX Series
Страница 17: ...2 5 Product Overview AC890PX AC Drive 890PX bottom wire entry ...
Страница 25: ...3 4 Installing the Drive AC890PX AC Drive Outline Drawing of AC890PX 132kW 400kW HC471581 page 2 of 2 ...
Страница 144: ...The Keypad 7 9 AC890PX AC Drive The Menu System Map ...
Страница 145: ...7 10 The Keypad AC890PX AC Drive The Menu System Map continued ...
Страница 159: ...7 24 The Keypad AC890PX AC Drive Assembly Procedure Mounting Dimensions for the Remote Mounted 6901 Keypad ...
Страница 250: ...Programming D 10 AC890PX AC Drive VALUE INPUT BREAK VALUE INPUT LOSS LEVEL BREAK ENABLE BREAK TYPE UNPROCESSED ...
Страница 328: ...Programming D 88 AC890PX AC Drive Functional Description ...
Страница 386: ...Programming D 146 AC890PX AC Drive Setpoint Drive Frequency Frequency 1 Frequency 2 ...
Страница 391: ...D 151 Programming AC890PX AC Drive Speed Rated Speed No Load Speed synchronous speed Rated Torque Torque ...