D-103
Programming
AC890PX AC Drive
Parameter Descriptions
ACCELERATION
PREF: 109.07
Default: 1.00 %
Range: 0.01 to 300.00 %
The acceleration at which the distance is added to the phase loop, set in units per second
2
.
ACTIVE
PREF: 109.05
Default: FALSE
Range: FALSE / TRUE
Active is set TRUE whenever the block is enable, i.e. the move distance is none zero..
DISTANCE LEFT
PREF: 109.06
Default: —.xx
Range: —.xx
A diagnostic showing the distance remaining before the move is complete.
OFFSET
PREF: 109.10
Default: —.xxxx
Range: —.xxxx
This diagnostic shows the total position offset generated by the move block. (1.0 = 1 load mechanical revolution)
Functional Description
This is a simple trapezoidal relative move function, which acts on each rising edge of the
Enable input. The slave shaft is moved a fixed distance at a rate given by the VELOCITY
parameter. A move must be complete before a new move will be registered.
Velocity
Distance
Содержание AC890PX Series
Страница 17: ...2 5 Product Overview AC890PX AC Drive 890PX bottom wire entry ...
Страница 25: ...3 4 Installing the Drive AC890PX AC Drive Outline Drawing of AC890PX 132kW 400kW HC471581 page 2 of 2 ...
Страница 144: ...The Keypad 7 9 AC890PX AC Drive The Menu System Map ...
Страница 145: ...7 10 The Keypad AC890PX AC Drive The Menu System Map continued ...
Страница 159: ...7 24 The Keypad AC890PX AC Drive Assembly Procedure Mounting Dimensions for the Remote Mounted 6901 Keypad ...
Страница 250: ...Programming D 10 AC890PX AC Drive VALUE INPUT BREAK VALUE INPUT LOSS LEVEL BREAK ENABLE BREAK TYPE UNPROCESSED ...
Страница 328: ...Programming D 88 AC890PX AC Drive Functional Description ...
Страница 386: ...Programming D 146 AC890PX AC Drive Setpoint Drive Frequency Frequency 1 Frequency 2 ...
Страница 391: ...D 151 Programming AC890PX AC Drive Speed Rated Speed No Load Speed synchronous speed Rated Torque Torque ...