D-175
Programming
AC890PX AC Drive
The DISABLED WORD 2 , ACTIVE WORD 2 and WARNINGS WORD 2 parameters use a four digit hexadecimal number
to identify individual trips. Each trip has a unique corresponding number as shown below.
Trip Name (MMI)
First Trip Value
Mask +
User Disable
Auto-restart
MOTOR OVERTEMP
17
0x0001
Yes
Yes
CURRENT LIMIT
18
0x0002
No
Yes
TRIP 19 (Reserved)
19
0x0004
No
No
24V FAILURE
20
0x0008
Yes
Yes
LOW SPEED OVER I
21
0x0010
No
Yes
PHASE FAIL
22
0x0020
No
Yes
ENCODER 1 FAULT
23
0x0040
Yes
Yes
DESAT (OVER I)
24
0x0080
No
Yes
VDC RIPPLE
25
0x0100
No
Yes
BRAKE SHORT CCT
26
0x0200
No
Yes
OVERSPEED
27
0x0400
Yes
Yes
ANALOG INPUT ERR
28
0x0800
No
Yes
INT DB RESISTOR 29
0x1000
No
Yes
TRIP 30 (Reserved)
30
0x2000
No
No
UNKNOWN
31
0x4000
No
Yes
OTHER
32
0x8000
No
Yes
Содержание AC890PX Series
Страница 17: ...2 5 Product Overview AC890PX AC Drive 890PX bottom wire entry ...
Страница 25: ...3 4 Installing the Drive AC890PX AC Drive Outline Drawing of AC890PX 132kW 400kW HC471581 page 2 of 2 ...
Страница 144: ...The Keypad 7 9 AC890PX AC Drive The Menu System Map ...
Страница 145: ...7 10 The Keypad AC890PX AC Drive The Menu System Map continued ...
Страница 159: ...7 24 The Keypad AC890PX AC Drive Assembly Procedure Mounting Dimensions for the Remote Mounted 6901 Keypad ...
Страница 250: ...Programming D 10 AC890PX AC Drive VALUE INPUT BREAK VALUE INPUT LOSS LEVEL BREAK ENABLE BREAK TYPE UNPROCESSED ...
Страница 328: ...Programming D 88 AC890PX AC Drive Functional Description ...
Страница 386: ...Programming D 146 AC890PX AC Drive Setpoint Drive Frequency Frequency 1 Frequency 2 ...
Страница 391: ...D 151 Programming AC890PX AC Drive Speed Rated Speed No Load Speed synchronous speed Rated Torque Torque ...