D-137
Programming
AC890PX AC Drive
Parameter Descriptions
INIT DONE
PREF: 133.17
Default: TRUE
Range: FALSE / TRUE
This is a diagnostic output indicating the state of the resolver init sequence:
INIT DONE = FALSE : init on going
INIT DONE = TRUE : init done
REVERSE CNT DIR
PREF: 133.18
Default: FALSE
Range: FALSE / TRUE
Set the count direction for the resolver feedback.
REVERSE CNT DIR = FALSE : the position is increasing if the motor is running in a clockwise direction looking to the front
shaft of the motor.
REVERSE CNT DIR = TRUE : the position is decreasing if the motor is running in a clockwise direction looking to the front
shaft of the motor.
SPEED FILTER
PREF: 133.19
Default: 100.00
Range: 10.00 to 1000.00 Hz
No action
PHASE SHIFT
PREF: 133.20
Default: 0.00
Range: 0.00 to 180.00°
No action
TRIP SELECTION
PREF: 133.21
Default: 2
Range: See below
Select the trip detection based on hardware and/or software detection:
Enumerated Value : Trip Selection
0 : HARD AND SOFT
The trip is based on hardware and software detection.
1 : HARD
The trip is only based on hardware detection.
2 : SOFT
The trip is only based on software detection.
Содержание AC890PX Series
Страница 17: ...2 5 Product Overview AC890PX AC Drive 890PX bottom wire entry ...
Страница 25: ...3 4 Installing the Drive AC890PX AC Drive Outline Drawing of AC890PX 132kW 400kW HC471581 page 2 of 2 ...
Страница 144: ...The Keypad 7 9 AC890PX AC Drive The Menu System Map ...
Страница 145: ...7 10 The Keypad AC890PX AC Drive The Menu System Map continued ...
Страница 159: ...7 24 The Keypad AC890PX AC Drive Assembly Procedure Mounting Dimensions for the Remote Mounted 6901 Keypad ...
Страница 250: ...Programming D 10 AC890PX AC Drive VALUE INPUT BREAK VALUE INPUT LOSS LEVEL BREAK ENABLE BREAK TYPE UNPROCESSED ...
Страница 328: ...Programming D 88 AC890PX AC Drive Functional Description ...
Страница 386: ...Programming D 146 AC890PX AC Drive Setpoint Drive Frequency Frequency 1 Frequency 2 ...
Страница 391: ...D 151 Programming AC890PX AC Drive Speed Rated Speed No Load Speed synchronous speed Rated Torque Torque ...