D-133
Programming
AC890PX AC Drive
Parameter Descriptions
CURRENT CONTROL
PREF: 114.08
Default: FALSE
Range: FALSE / TRUE
This parameter is used to designate if the drive is operating in a current control mode (TRUE), or in a closed-loop voltage
control mode (FALSE).
HARDWARE SYNC
PREF: 114.25
Default:FALSE
Range:TRUE/FALSE
This parameter is used to designate whether the drive is synchronised using 8902LS line sync option (TRUE), or a sensorless
algorithm in software (FALSE).
SYNCHRONIZING
PREF: 114.09
Default: FALSE
Range: FALSE / TRUE
This diagnostic reads True during the mains synchronisation period. This occurs when the drive is first run in 4Q Regen
Control Mode. This synchronising period lasts for 100ms.
SYNCHRONIZED
PREF: 114.10
Default: FALSE
Range: FALSE / TRUE
This diagnostic reads True when mains synchronisation has been successfully completed.
PHASE LOSS
PREF: 114.11
Default: FALSE
Range: FALSE / TRUE
This diagnostic reads True if the drive suspects there is a missing input phase from the mains supply.
CLOSE PRECHARGE
PREF: 114.12
Default: TRUE
Range: FALSE / TRUE
This diagnostic controls the operation of the external precharge contactor required by the 4Q Regen Control Mode.
ENABLE DRIVE
PREF: 114.13
Default: FALSE
Range: FALSE / TRUE
This diagnostic is used to enable drives on a common dc link system supplied by a drive using the 4Q Regen Control Mode.
The diagnostic reads True if mains synchronisation has been successful and the drive is Healthy.
Содержание AC890PX Series
Страница 17: ...2 5 Product Overview AC890PX AC Drive 890PX bottom wire entry ...
Страница 25: ...3 4 Installing the Drive AC890PX AC Drive Outline Drawing of AC890PX 132kW 400kW HC471581 page 2 of 2 ...
Страница 144: ...The Keypad 7 9 AC890PX AC Drive The Menu System Map ...
Страница 145: ...7 10 The Keypad AC890PX AC Drive The Menu System Map continued ...
Страница 159: ...7 24 The Keypad AC890PX AC Drive Assembly Procedure Mounting Dimensions for the Remote Mounted 6901 Keypad ...
Страница 250: ...Programming D 10 AC890PX AC Drive VALUE INPUT BREAK VALUE INPUT LOSS LEVEL BREAK ENABLE BREAK TYPE UNPROCESSED ...
Страница 328: ...Programming D 88 AC890PX AC Drive Functional Description ...
Страница 386: ...Programming D 146 AC890PX AC Drive Setpoint Drive Frequency Frequency 1 Frequency 2 ...
Страница 391: ...D 151 Programming AC890PX AC Drive Speed Rated Speed No Load Speed synchronous speed Rated Torque Torque ...