Drag
6
Specify
Originator Variable
and its
Size [Byte]
for the tag set Net_Out1 added in step 5.
Here, specify
Net_In1
for
Originator Variable
and
2
for its
Size [Byte]
.
Change the other settings as required.
You can set the following items in the connection settings.
Name
Setting Methods
Target Device
Select the target device.
Connection Name
Any name can be given to the connection (32 single-byte characters
max.).
Connection I/O Type
Input Only (Tag type) is selected if the EtherNet/IP connection is es-
tablished on a CS1W-EIP21, CJ1W-EIP21, CJ2B-EIP21, CJ2M-
EIP21, CJ1W-EIP21(CJ2), CJ1W-EIP21(NJ), NX701 or NX102-
£££
£
, NX1P2 or NJ501-
££££
, NJ301-
££££
or NJ101.
When you create EtherNet/IP connection for another target device,
select the connection I/O type specified in the device's EDS file.
Use the
Input Only (ID type)
setting when the originator is a node
from another manufacturer and does not support connection settings
with a Tag type setting.
Input/Output
The connection's input/output is automatically displayed based on the
selected connection.
Input Only: Just Input is displayed.
Target Variable
Select the target node's tag set to assign it.
•
Input is specified for
Input/Output
: Select the target's output (pro-
duce) tag set.
•
Output is specified for
Input/Output
: Select the target's input (con-
sume) tag set.
Size [Byte]
The data sizes of the target variables are displayed.
Appendices
A-16
NJ/NX-series CPU Unit Built-in EtherNet/IP Port User’s Manual (W506)
Содержание Sysmac NX1P2-10 1 Series
Страница 8: ...Manual Structure 6 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 34: ...Revision History 32 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 174: ...6 Testing Communications 6 4 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 354: ...8 CIP Message Communications 8 92 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 388: ...9 Socket Service 9 34 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 394: ...10 Modbus TCP Master Function 10 6 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 430: ...12 FTP Client 12 14 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 569: ...I Index I 1 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506 I...
Страница 576: ...Index I 8 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 577: ......