![Omron Sysmac NX1P2-10 1 Series Скачать руководство пользователя страница 167](http://html1.mh-extra.com/html/omron/sysmac-nx1p2-10-1-series/sysmac-nx1p2-10-1-series_user-manual_1633435167.webp)
Recognition 1
Setting
Description
Default
Recognition method
Set the method to use to specify SNMP managers for which ac-
cess is permitted.
•
IP address
•
Host name
Make these settings to permit access by only certain SNMP
managers.
Access is not allowed unless an IP address or host name is set.
IP address
IP address
Set the IP address of the SNMP manager.
If the default setting of 0.0.0.0 is used, access by all SNMP man-
agers is permitted.
(Set this setting if
Recognition method
in Recognition 1 is set to
the
IP address
Option.)
None
Host name
Set the host name of the SNMP manager.
(Set this setting if
Recognition method
in Recognition 1 is set to
the
Host name
Option.)
(You can use up to 200 single-byte alphanumeric characters,
dots, and hyphens with up to 63 single-byte alphanumeric char-
acters between dots.)
None
Community name
Set the community name to enable the SNMP manager to ac-
cess information from the built-in EtherNet/IP port.
(Single-byte alphanumeric characters, dots, and hyphens: 255
characters max.)
public
Recognition 2
Setting
Description
Default
Recognition 2
Specify whether to use the recognition 2 settings.
•
Use
•
Do not use
Do not use
Recognition method
Set the method to use to specify SNMP managers for which ac-
cess is permitted.
•
IP address
•
Host name
Make these settings to permit access by only certain SNMP man-
agers.
Access is not allowed unless an IP address or host name is set.
IP address
IP address
Set the IP address of the SNMP manager.
If the default setting of 0.0.0.0 is used, access by all SNMP man-
agers is permitted.
(Set this setting if
Recognition method
in Recognition 2 is set to
the
IP address
Option.)
None
Host name
Set the host name of the SNMP manager.
(Set this setting if
Recognition method
in Recognition 2 is set to
the
Host name
Option.)
(You can use up to 200 single-byte alphanumeric characters,
dots, and hyphens for a host name, including up to 63 single-byte
alphanumeric characters between two dots.)
None
Community name
Set the community name to enable the SNMP manager to ac-
cess information from the built-in EtherNet/IP port.
(Single-byte alphanumeric characters, dots, and hyphens: 255
characters max.)
public
5 Sysmac Studio Settings for the Built-in EtherNet/IP Port
5-13
NJ/NX-series CPU Unit Built-in EtherNet/IP Port User’s Manual (W506)
5-5 SNMP Settings Display
5
Содержание Sysmac NX1P2-10 1 Series
Страница 8: ...Manual Structure 6 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 34: ...Revision History 32 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 174: ...6 Testing Communications 6 4 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 354: ...8 CIP Message Communications 8 92 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 388: ...9 Socket Service 9 34 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 394: ...10 Modbus TCP Master Function 10 6 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 430: ...12 FTP Client 12 14 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 569: ...I Index I 1 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506 I...
Страница 576: ...Index I 8 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 577: ......