General sta-
tus code
(hex)
Error name
Cause
02
Resource unavailable
Resources needed for the object to perform the requested
service were unavailable.
0C
Object state conflict
The object cannot perform the requested service in its cur-
rent mode/state.
10
Device state conflict
This service could not change because the transition to the
parameter write mode is in progress.
13
Not enough data
Data required for the execution of the required service is in-
sufficient.
15
Too much data
Extra data for the execution of the required service is includ-
ed.
1F
Vendor specific error
The service could not be executed due to internal reasons.
20
Invalid parameter
•
The Unit number is out of the supported range.
•
The Unit does not exist.
Read Total Power On Time (Service Code: 38 hex)
Read the total power on time of the specified NX Unit.
Request Data Format
Parameter name
Data type
Description
Service
USINT
Read total power on time service: 38 hex
Request Path Size
USINT
Size of Request Path: 02 hex
Request Path
Padded EPATH
Request path: 2074 2401 hex
Class ID: 74 hex
Instance ID: 01 hex
Unit No
UINT
Unit number
0001 to 0020 hex: NX Unit
0000, 0021 hex or above: Not supported
Response Data Format
When the processing is successful
Parameter name
Data type
Description
Reply Service
USINT
Read total power on time service response: B8 hex
Reserved
USINT
Reserved: 00 hex
General Status
USINT
Code indicating normal: 00 hex
Size of Additional Status
USINT
Size of Additional Status: 00 hex
Total power on time
ULINT
Total power on time of NX Units.
When the processing failed
Parameter name
Data type
Description
Reply Service
USINT
Read total power on time service response: B8 hex
Reserved
USINT
Reserved: 00 hex
General Status
USINT
Current error code defined by CIP
Size of Additional Status
USINT
Size of Additional Status: 00 hex or 01 hex
8 CIP Message Communications
8-58
NJ/NX-series CPU Unit Built-in EtherNet/IP Port User’s Manual (W506)
Содержание Sysmac NX1P2-10 1 Series
Страница 8: ...Manual Structure 6 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 34: ...Revision History 32 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 174: ...6 Testing Communications 6 4 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 354: ...8 CIP Message Communications 8 92 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 388: ...9 Socket Service 9 34 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 394: ...10 Modbus TCP Master Function 10 6 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 430: ...12 FTP Client 12 14 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 569: ...I Index I 1 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506 I...
Страница 576: ...Index I 8 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 577: ......