In this example, right click
Built-in EtherNet/IP Port Settings
for the originator device and se-
lect
Edit
from the menu to open the EtherNet/IP Connection Setting Tab Page.
3
Click the
(Show Tag Set Display) icon in the EtherNet/IP Connection Setting Tab Page.
4
Click the
Input
tab to switch to the
Input
Tab Page. Register the tag set and the tag.
Use one of the following methods to register the tag set and the tag.
•
Independ-
ent registra-
tion
:
Manually registers network variables in the Controller as tags.
•
Batch regis-
tration
:
Registers all network variables in the Controller as tags at the same time.
5
Register tags and tag sets independently.
1) Right-click anywhere in the Input Tab Page of the EtherNet/IP Connection Setting Tab Page
and select
Create New Tag Set
from the menu.
2) Enter the tag set name,
Net_In1
, directly into the list in the
Input
Tab Page.
3) Right-click anywhere in the Input Tab Page and select
Create New Tag
from the menu.
4) Enter tag name
Net_In1
.
Tag set name
Tag name
Precautions for Correct Use
Any name can be specified for the tag set if the name matches one of the registered network
variable names in the Controller.
As you enter characters (or immediately after you press the Ctrl + Space Keys), the Sysmac
Studio Entry Assistance provides a list of variable names registered in the Controller. Select the
variable name from the list.
Appendices
A-12
NJ/NX-series CPU Unit Built-in EtherNet/IP Port User’s Manual (W506)
Содержание Sysmac NX1P2-10 1 Series
Страница 8: ...Manual Structure 6 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 34: ...Revision History 32 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 174: ...6 Testing Communications 6 4 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 354: ...8 CIP Message Communications 8 92 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 388: ...9 Socket Service 9 34 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 394: ...10 Modbus TCP Master Function 10 6 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 430: ...12 FTP Client 12 14 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 569: ...I Index I 1 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506 I...
Страница 576: ...Index I 8 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 577: ......