Direct Connection via Ethernet (1:1 Connection
with AutoIP)
Ethernet Connection via Hub (1:N Connection)
Ethernet
*1. An Ethernet switch is not necessarily required.
*2. You can use a straight or cross Ethernet cable to
connect.
*3. With the NX701 CPU Unit and NX102 CPU Unit,
1:1 connection is possible only on the built-in
EtherNet/IP port 1.
Ethernet
*1. An Ethernet switch is required to connect. Refer
to
2-1-4 Precautions for Ethernet Switch Selec-
• Connection from USB Across Ethernet
Remote Connection via USB
(1:N Connection)
Ethernet
USB
*1. An NJ/NX-series Controller with a USB port is re-
quired to connect.
*2. An Ethernet switch is required to connect. Refer
to
2-1-4 Precautions for Ethernet Switch Selec-
Additional Information
• Auto IP automatically assigns IP addresses in Windows 98 and later operating systems.
Unique IP addresses are automatically assigned from the address
169.254.0.0 to
169.254.255.255
.
• If the Sysmac Studio is connected online via a built-in EtherNet/IP port, changing the IP ad-
dress of the connected built-in EtherNet/IP port will cause a timeout on the Sysmac Studio.
In the case, switch the Sysmac Studio status to offline, restore the original IP address of the
connected built-in EtherNet/IP port, and then switch back the Sysmac Studio status to online.
This will allow you to reconnect.
Precautions for Correct Use
If there is more than one node with the same IP address in the EtherNet/IP network, the built-in
EtherNet/IP port will connect to the node that is detected first.
Note that an IP Address Duplication Error will not be detected in this case.
Online Connection Procedure
Connect the CPU Unit and the computer that runs the Sysmac Studio via USB or Ethernet, and then
perform the following procedure.
4 Determining IP Addresses
4-9
NJ/NX-series CPU Unit Built-in EtherNet/IP Port User’s Manual (W506)
4-2 Built-in EtherNet/IP Port IP Address Settings
4
4-2-3
Online Connection
Содержание Sysmac NX1P2-10 1 Series
Страница 8: ...Manual Structure 6 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 34: ...Revision History 32 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 174: ...6 Testing Communications 6 4 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 354: ...8 CIP Message Communications 8 92 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 388: ...9 Socket Service 9 34 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 394: ...10 Modbus TCP Master Function 10 6 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 430: ...12 FTP Client 12 14 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 569: ...I Index I 1 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506 I...
Страница 576: ...Index I 8 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 577: ......