13
Click the
OK
Button in the
Edit Device Parameters
Dialog Box.
Importing Variables with a Network Publish Attribute Created in the
Sysmac Studio to the Network Configurator
You can create network variables in the Sysmac Studio and import these variables to the Network
Configurator to assign them to tags and tag sets. Use the following procedure.
Exporting Global Variables on the Sysmac Studio
1
Create a global variable on the global variable table of the Sysmac Studio and select
Input
or
Output
for the Network Publish attribute of the variable.
2
Select
Export Global Variables
-
Network Configurator...
from the
Tools
Menu.
Any global variables with
Input
or
Output
set for the Network Publish attribute are imported
from the csv file through the import procedure described below ( Importing to the Network Con-
figurator).
Importing to the Network Configurator
Precautions for Correct Use
Variables with a Network Publish attribute that have variable names that are the same as the
I/O memory address notation, such as, "0000" and "H0000" are not exported to CSV files.
• Variable names that contain only single-byte numerals (Example: 001)
• Variable names with the following single-byte letters (uppercase or lowercase) followed by
single-byte numerals
• H (Example: H30)
• W (Example: w30)
• D (Example: D100)
• E0_ to E18_ (Example: EA_100)
1
From the devices registered on the Network Configurator, select and double-click the icon of
the device for which you want to import the variable with a Network Publish attribute. Then, the
Edit Device Parameters
Dialog Box is displayed.
Or, right-click the icon to display the pop-up menu, and select
Device
-
Parameter
-
Edit
.
2
Click the
Tag Sets
Tab at the top of the
Edit Device Parameters
Dialog Box. Select
Import
from File
from the
To/From File
Button.
7 Tag Data Link Functions
7-33
NJ/NX-series CPU Unit Built-in EtherNet/IP Port User’s Manual (W506)
7-2 Setting T
ag Data Links
7
7-2-4
Creating T
ags and T
ag Sets
Содержание Sysmac NX1P2-10 1 Series
Страница 8: ...Manual Structure 6 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 34: ...Revision History 32 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 174: ...6 Testing Communications 6 4 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 354: ...8 CIP Message Communications 8 92 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 388: ...9 Socket Service 9 34 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 394: ...10 Modbus TCP Master Function 10 6 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 430: ...12 FTP Client 12 14 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 569: ...I Index I 1 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506 I...
Страница 576: ...Index I 8 NJ NX series CPU Unit Built in EtherNet IP Port User s Manual W506...
Страница 577: ......