![Omron SYSMAC C200H Скачать руководство пользователя страница 48](http://html1.mh-extra.com/html/omron/sysmac-c200h/sysmac-c200h_operation-manual_742423048.webp)
35
Level 0
Level 1
Bit (body of table shows node numbers)
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
AR 08
AR 12
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
AR 09
AR 13
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
AR 10
AR 14
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
AR 11
AR 15
49
50
51
52
53
54
55
56
57
58
59
60
61
62
*
**
*Communication Controller Error Flag
**EEPROM Error Flag
3-5-5
SYSMAC LINK/SYSMAC NET Link System Service Time
(CPU11-E only)
AR 16 provides the time allocated to servicing operating level 0 of the SYS-
MAC LINK System and/or SYSMAC NET Link System during each cycle
when a SYSMAC LINK Unit and/or SYSMAC NET Link Unit is mounted to a
Rack.
AR 17 provides the time allocated to servicing operating level 1 of the SYS-
MAC LINK System and/or SYSMAC NET Link System during each cycle
when a SYSMAC LINK Unit and/or SYSMAC NET Link Unit is mounted to a
Rack.
These times are recorded in 4-digit BCD to tenths of a millisecond (000.0 ms
to 999.9 ms) and are refreshed every cycle.
Bits
15 to 12
11 to 08
07 to 04
03 to 00
10
2
10
1
10
0
10
–1
3-5-6
Calendar/Clock Area and Bits (CPU11-E Only)
Calendar/Clock Area
If AR 2114 (Stop Bit) is OFF, then the date, day, and time will be available in
BCD in AR 18 to AR 20 and AR 2100 to AR 2108 as shown below. This area
can also be controlled with AR 2113 (Seconds Round-off Bit) and AR 2115
(Set Bit).
Bits
Contents
Possible values
AR 1800 to AR 1807
Seconds
00 to 59
AR 1808 to AR 1815
Minutes
00 to 59
AR 1900 to AR 1907
Hours
00 to 23 (24-hour system)
AR 1908 to AR 1915
Day of month
01 to 31 (adjusted by month and for leap year)
AR 2000 to AR 2007
Month
1 to 12
AR 2008 to AR 2015
Year
00 to 99 (Rightmost two digits of year)
AR 2100 to AR 2107
Day of week
00 to 06 (00: Sunday; 01: Monday; 02: Tuesday; 03: Wednesday; 04:
Thursday; 05: Friday; 06: Saturday)
Seconds Round-off Bit
AR 2113 is turned ON to round the seconds of the Calendar/clock Area to
zero, i.e., if the seconds is 29 or less, it is merely set to 00; if the seconds is
30 or greater, the minutes is incremented by 1 and the seconds is set to 00.
Stop Bit
AR 2114 is turned OFF to enable the operation of the Calendar/clock Area
and ON to stop the operation.
Set Bit
AR 2115 is used to set the Calendar/clock Area as described below. This
data must be in BCD and must be set within the limits for the Calendar/clock
Area given above.
AR Area
Section 3-5
Содержание SYSMAC C200H
Страница 1: ...OPERATION MANUAL C200H CPU01 E 03 E 11 E SYSMAC Programmable Controllers Cat No W130 E1 05 ...
Страница 2: ...C200H Programmable Controllers CPU01 E 03 E 11 E Operation Manual Revised June 2003 ...
Страница 3: ...iv ...
Страница 5: ...vi ...
Страница 8: ...TABLE OF CONTENTS ix Glossary 345 Index 363 Revision History 369 ...
Страница 342: ...336 Programmer Program Date Page Word Contents Notes Word Contents Notes Data Storage ...
Страница 374: ...Cat No W130 E1 05 C200H Programmable Controllers CPU01 E 03 E 11 E OPERATION MANUAL ...