27
Multilevel PC Link Systems
Flag type
Bit no.
SR 247
SR 248
SR 249
SR 250
Run flags
00
Unit #8,
level 1
Unit #0,
level 1
Unit #8,
level 0
Unit #0,
level 0
01
Unit #9,
level 1
Unit #1,
level 1
Unit #9,
level 0
Unit #1,
level 0
02
Unit #10,
level 1
Unit #2,
level 1
Unit #10,
level 0
Unit #2,
level 0
03
Unit #11,
level 1
Unit #3,
level 1
Unit #11,
level 0
Unit #3,
level 0
04
Unit #12,
level 1
Unit #4,
level 1
Unit #12,
level 0
Unit #4,
level 0
05
Unit #13,
level 1
Unit #5,
level 1
Unit #13,
level 0
Unit #5,
level 0
06
Unit #14,
level 1
Unit #6,
level 1
Unit #14,
level 0
Unit #6,
level 0
07
Unit #15,
level 1
Unit #7,
level 1
Unit #15,
level 0
Unit #7,
level 0
Error flags
08
Unit #8,
level 1
Unit #0,
level 1
Unit #8,
level 0
Unit #0,
level 0
09
Unit #9,
level 1
Unit #1,
level 1
Unit #9,
level 0
Unit #1,
level 0
10
Unit #10,
level 1
Unit #2,
level 1
Unit #10,
level 0
Unit #2,
level 0
11
Unit #11,
level 1
Unit #3,
level 1
Unit #11,
level 0
Unit #3,
level 0
12
Unit #12,
level 1
Unit #4,
level 1
Unit #12,
level 0
Unit #4,
level 0
13
Unit #13,
level 1
Unit #5,
level 1
Unit #13,
level 0
Unit #5,
level 0
14
Unit #14,
level 1
Unit #6,
level 1
Unit #14,
level 0
Unit #6,
level 0
15
Unit #15,
level 1
Unit #7,
level 1
Unit #15,
level 0
Unit #7,
level 0
If the PC is in a Multilevel PC Link System and the content of word 248 is
02FF, then PC Link Units #0 through #7 of in the PC Link Subsystem as-
signed operating level 1 would be in RUN mode, and PC Link Unit #1 in the
same Subsystem would have an error. The hexadecimal digits and corre-
sponding binary bits of word 248 would be as shown below.
Bit no.
15
00
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Binary
0 0 0 0
0 0 1 0
1 1 1 1
1 1 1 1
Hex
0
2
F
F
3-4-3
Forced Status Hold Bit (CPU11-E Only)
SR 25211 determines whether or not the status of bits that have been force-
set or force-reset is maintained when switching between PROGRAM and
MONITOR mode to start or stop operation. If SR 25211 is ON, bit status will
be maintained; if SR 25211 is OFF, all bits will return to default status when
operation is started or stopped. The Force Status Hold Bit is only effective
when enabled with the Set System instruction (SYS(49)).
The status of SR 25211 in not affected by a power interruption unless the I/O
table is registered; in that case, SR 25211 will go OFF.
Application Example
SR Area
Section 3-4
Содержание SYSMAC C200H
Страница 1: ...OPERATION MANUAL C200H CPU01 E 03 E 11 E SYSMAC Programmable Controllers Cat No W130 E1 05 ...
Страница 2: ...C200H Programmable Controllers CPU01 E 03 E 11 E Operation Manual Revised June 2003 ...
Страница 3: ...iv ...
Страница 5: ...vi ...
Страница 8: ...TABLE OF CONTENTS ix Glossary 345 Index 363 Revision History 369 ...
Страница 342: ...336 Programmer Program Date Page Word Contents Notes Word Contents Notes Data Storage ...
Страница 374: ...Cat No W130 E1 05 C200H Programmable Controllers CPU01 E 03 E 11 E OPERATION MANUAL ...