244
The following example shows the displays that appear when Restore Status
is carried out normally.
00000
00000
00000FORCE RELE?
00000FORCE RELE
END
7-1-4
Hexadecimal/BCD Data Modification
When the Bit/Digit Monitor operation is being performed and a BCD or hexa-
decimal value is leftmost on the display, CHG can be input to change the
value. SR words cannot be changed.
If a timer or counter is leftmost on the display, the PV will be displayed and
will be the value changed. See 7-1-10 Changing Timer/Counter SV for the
procedure to change SV. PV can be changed in MONITOR mode only when
the timer or counter is operating.
To change contents of the leftmost word address, press CHG, input the de-
sired value, and press WRITE
Key Sequence
Word currently
monitored on
left of display.
[ Data ]
Example
Monitoring Operation and Modifying Data
Section 7-1