Name
Function
Reference page
Password Input
Prompts the user for the access password.
62
Buzzer ON/OFF
Controls whether the buzzer will sound for keystroke inputs.
63
Data Clear
Used to erase data, either selectively or totally, from the Program Memory and the
IR, AR, HR, DM, and TC areas.
63
I/O Table Register
Registers the I/O table after initial entry or subsequent amendments.
65
I/O Table Verify
Checks the I/O Table against the actual arrangement of I/O Units.
66
I/O Table Read
Displays the Unit type, location, allocated I/O word, and word multiplier (where applica-
ble).
67
NET Link Table Transfer
Transfers a copy of the NET Link System’s Link Table to the user memory (UM) area.
70
I/O Table Delete
Deletes the entire I/O Table.
69
Address Designation
Displays the specified address.
72
Program Input
Used to edit or input program instructions.
73
Program Read
Allows the user to scroll through the program address-by-address. In RUN and
MONITOR modes, status of bits is also given.
72
Program Search
Searches a program for the specified data address or instruction.
79
Instruction Insert
Instruction Delete
Allows a new instruction to be inserted before the displayed instruction, or deletes
the displayed instruction (respectively).
73
Program Check
Checks the completed program for syntax errors (up to three levels in H-type PCs).
76
Error Message Read
Displays error messages in sequence, starting with the most severe messages.
264
Bit/Word Monitor
Displays the specified address whose operand is to be monitored. In RUN or MONTR
mode it will show the status of the operand for any bit or word in any data area.
238
3-word Monitor
Simultaneously monitors three consecutive words.
246
Forced Set/Reset
Set: Used to turn ON bits or timers, or to increment counters currently displayed on
the left of the screen.
Reset: Used to turn OFF bits, or to reset timers or counters.
241
Clear Forced Set/Reset
Simultaneously clears all forced bits within the currently displayed word.
243
Hex/BCD Data Change
Used to change the value of the leftmost BCD or hexadecimal word displayed dur-
ing a Bit/Word Monitor operation.
244
Binary Data Change
Changes the value of 16-bit words bit-by-bit. Bits can be changed temporarily or
permanently to the desired status.
249
SV Change/SV Reset
Alters the SV of a timer or counter either by incrementing or decrementing the val-
ue, or by overwriting the original value with a new one.
251
3-word Change
Used to change the value of a word displayed during a 3-word Monitor operation.
247
Cycle Time Display
Measures the duration of the current cycle. Cycle times will vary according to the
execution conditions which exist in each cycle.
78
Hex–ASCII Display Change
Converts 4-digit hexadecimal data in the DM area to ASCII and vice-versa.
245
Binary Monitor
Displays the monitored area in binary format.
248
Program Memory Save
Saves Program Memory to tape.
254
Program Memory Restore
Reads Program Memory from tape.
256
Program Memory Compare
Compares Program Memory data on tape with that in the Program Memory area.
256
DM Data Save, Restore,
Compare
The save, restore, and compare tape operations for DM area data.
258
Содержание SYSMAC C200H
Страница 1: ...OPERATION MANUAL C200H CPU01 E 03 E 11 E SYSMAC Programmable Controllers Cat No W130 E1 05 ...
Страница 2: ...C200H Programmable Controllers CPU01 E 03 E 11 E Operation Manual Revised June 2003 ...
Страница 3: ...iv ...
Страница 5: ...vi ...
Страница 8: ...TABLE OF CONTENTS ix Glossary 345 Index 363 Revision History 369 ...
Страница 342: ...336 Programmer Program Date Page Word Contents Notes Word Contents Notes Data Storage ...
Страница 374: ...Cat No W130 E1 05 C200H Programmable Controllers CPU01 E 03 E 11 E OPERATION MANUAL ...