157
Some example Di values and the word-to-digit conversions that they produce
are shown below.
0
1
2
3
R
Di: 0011
S
S + 1
0
1
2
3
S
S + 1
S + 2
S + 3
Di: 0030
R
S
S + 1
S + 2
S + 3
0
1
2
3
Di: 0032
R
Di: 0013
0
1
2
3
S
S + 1
R
Flags
ER:
Undefined digit designator, or S plus number of digits exceeds a data
area.
Content of a source word is zero.
Indirectly addressed DM word is non-existent. (Content of
*
DM word
is not BCD, or the DM area boundary has been exceeded.)