![Omron SYSMAC C200H Скачать руководство пользователя страница 321](http://html1.mh-extra.com/html/omron/sysmac-c200h/sysmac-c200h_operation-manual_742423321.webp)
Appendix B
Programming Instructions
313
IR
SR
HR
TR
AR
LR
TC
DM
#
00000 to 23515
23600 to 25507
HR 0000 to 9915
TR 0 to 7
AR 0000 to 2715
LR 0000 to 6315
TC 000 to 511
Read/Wr: DM 0000 to DM 0999
Rd only: DM 1000 to DM 1999
0000 to 9999
or 0000 to FFFF
These footnote tables show the actual ranges of all data areas. Bit numbers are provided (except for DM and TC areas); remove the rightmost two digits for word numbers.
Data Areas
Name
Mnemonic
Operand Data Areas
Function
Symbol
NETWORK RECEIVE
(@)RECV(98)
(CPU11-E)
RECV(98)
S
D
C
n: no. of words to be transmitted, 0 to 1000
Response monitor time
(0.1 to 25.4 s)
Source node no.
(0 to 62)
n: no. of words to be transmitted (0 to 1000)
Network no. (0 to 127)
Source node no.
(0 to 126)
Transfers data from the source words (S is
the first word) from node N of the specified
network (in a SYSMAC LINK or NET Link
System) to the destination words starting
at D. The format of the control words va-
ries depending on the type of system. In
both types of systems, the first control
word (C) gives the number of words to be
transferred.
For NET Link Systems, in the second word
(C+1), bit 14 specifies the system (0 for
system 1, and 1 for system 0), and the
rightmost 7 bits define the network num-
ber. The left half of word C+2 specifies the
source port (00: NSB, 01/02: NSU), and
the right half specifies the source node
number.
For SYSMAC LINK Systems, the right half
of C+1 specifies the response monitoring
time (default 00: 2 s, FF: monitoring dis-
abled), the next digit to the left gives the
maximum number of re-transmissions (0
to 15) that the PC will attempt if no re-
sponse signal is received. Bit 13 specifies
whether a response is needed (0) or not
(1), and bit 14 specifies the system num-
ber (0 for system 1, and 1 for system 0).
The right half of C+2 gives the source
node number.
C
C+1
C+2
C
C+1
NET Link
SYSMAC LINK
0X00
0000
Source port no.
(NSB: 00, NSU: 01/02)
0XX0
Re-trans-
missions
0000
0000
C+2
Destination node
Source node N
S
S+1
S+n–1
D
D+1
D+n–1
S:
IR
SR
HR
AR
LR
TC
DM
C/D:
IR
HR
AR
LR
TC
DM
Содержание SYSMAC C200H
Страница 1: ...OPERATION MANUAL C200H CPU01 E 03 E 11 E SYSMAC Programmable Controllers Cat No W130 E1 05 ...
Страница 2: ...C200H Programmable Controllers CPU01 E 03 E 11 E Operation Manual Revised June 2003 ...
Страница 3: ...iv ...
Страница 5: ...vi ...
Страница 8: ...TABLE OF CONTENTS ix Glossary 345 Index 363 Revision History 369 ...
Страница 342: ...336 Programmer Program Date Page Word Contents Notes Word Contents Notes Data Storage ...
Страница 374: ...Cat No W130 E1 05 C200H Programmable Controllers CPU01 E 03 E 11 E OPERATION MANUAL ...