3-7
3-1 Driver Specifications
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
3
Specifications
Encoder phase-Z error
A phase Z pulse was not detected regularly.
Encoder CS signal error
A logic error was detected in the CS signal.
External scale communications error
An error was detected in external scale connection and communications
data.
External scale status error
An external scale error code was detected.
Phases-A, B and Z connection error
An error was generated for connection of phases A, B, and Z of external
scale.
Motor non-conformity
The combination of the Servomotor and Servo Drive is not appropriate.
The encoder was not connected when the power supply was turned ON.
Error detection
Description