8-3 Vibration Suppression Parameters
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
8
Parameters Details
Set vibration frequency 3 to suppress vibration at the end of the load in damping control.
Measure the frequency of vibration at the end of the load and make the setting in units of 0.1 Hz.
Setting frequency is 1.0 to 200.0 Hz. The function will be disabled if the setting is 0 to 0.9 Hz.
Refer to "6-1 Damping Control" (P.6-1) for more information on settings.
First set the Vibration Frequency 3 (Pn218). Then reduce the setting if torque saturation occurs or
increase the setting to increase operation speed. Normally, use a setting of 0.
Set value is restricted in the following manner.
Upper limit: Corresponding vibration frequency
Lower limit: Vibration fre vibration filter setting
≥
100
Refer to "6-1 Damping Control" (P.6-1) for more information on settings.
Set vibration frequency 4 to suppress vibration at the end of the load in damping control.
Measure the frequency of vibration at the end of the load and make the setting in units of 0.1 Hz.
Setting frequency is 1.0 to 200.0 Hz. The function will be disabled if the setting is 0 to 0.9 Hz.
Refer to "6-1 Damping Control" (P.6-1) for more information on settings.
First set the Vibration Frequency 4 (Pn220). Then reduce the setting if torque saturation occurs or
increase the setting to increase operation speed. Normally, use a setting of 0.
Set value is restricted in the following manner.
Upper limit: Corresponding vibration frequency
Lower limit: Vibration fre vibration filter setting
≥
100
Refer to "6-1 Damping Control" (P.6-1) for more information on settings.
Pn218
Vibration Frequency 3
Setting
range
0 to 2,000
Unit
0.1 Hz
Default
setting
0
Power OFF
and ON
−
Position
Pn219
Vibration Filter 3 Setting
Setting
range
0 to 1,000
Unit
0.1 Hz
Default
setting
0
Power OFF
and ON
−
Position
Pn220
Vibration Frequency 4
Setting
range
0 to 2,000
Unit
0.1 Hz
Default
setting
0
Power OFF
and ON
−
Position
Pn221
Vibration Filter 4 Setting
Setting
range
0 to 1,000
Unit
0.1 Hz
Default
setting
0
Power OFF
and ON
−
Position
Содержание OMNUC G5
Страница 26: ......
Страница 82: ......
Страница 222: ......
Страница 266: ......
Страница 356: ......
Страница 364: ......
Страница 430: ......
Страница 542: ......
Страница 543: ...I OMNUC G5 SERIES AC SERVOMOTOR AND SERVO DRIVE USER S MANUAL Index...
Страница 548: ...Index 5 Index I...
Страница 549: ......