12-6
12-1 Connection Examples
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
12
Appendix
Connection Example 6: Connecting to SYSMAC CP1H-YxxDT-D
Precautions for Correct Use
Incorrect signal wiring can cause damage to units and the driver.
Leave unused signal lines open and do not wire them.
Do not share the power supply for brakes (24 VDC) with the 24-VDC power supply for controls.
The diode recommended for surge absorption is the RU 2 (Sanken Electric Co., Ltd.) or the
equivalent.
S
CN1
CNA
4
5
6
30
39
7
29
37
11
3
L1
L2
U
V
W
ZCOM
INP
RUN
/ALM
FG
Z
X1
XB
24 VDC
R
T
NFB
ON
OFF
X1
MC1
X1
24 VDC
BKIR
25
19
MC1
X1
L3
M
Red
White
Blue
Green/Yellow
R88M-Kx
CN2
Motor power cables
E
24 VDC
Encoder cables
B
Brake cables
XB
CNB
B1
B3
B2
BKIRCOM
10
ALMCOM
36
PL
SUP
MC2
MC1
MC2
MC1 MC2
MC2
ECRST
Reactor
CP1H-Y20DT-D
R88-KTx
Output terminal block
CW0
+
CW0
−
CCW0
+
CCW0
−
24-VDC input terminal (
+
)
Input terminal block
Shell
+
CW
−
CW
+
CCW
−
CCW
+
24VIN
Pulse
Output
0
Noise filter
Main circuit power supply
24-VDC input terminal (
−
)
COM(0CH)
Servo error display
Main circuit contact
surge suppressor
Pulse 0 origin input signal (0 word, bit 00)
Pulse 0 origin proximity input signal (0 word, bit 01)
Origin search 0 (101 word, bit 02)
COM (for 101 word, bit 00 to 03)
3-phase 200 to 240 VAC 50/60 Hz
Ground to
100
Ω
or less
Содержание OMNUC G5
Страница 26: ......
Страница 82: ......
Страница 222: ......
Страница 266: ......
Страница 356: ......
Страница 364: ......
Страница 430: ......
Страница 542: ......
Страница 543: ...I OMNUC G5 SERIES AC SERVOMOTOR AND SERVO DRIVE USER S MANUAL Index...
Страница 548: ...Index 5 Index I...
Страница 549: ......