
12-20
12-2 Parameter List
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
12
Appendix
Interface Monitor Setting Parameters
324
External Feedback
Pulse Dividing
Numerator
Selection
Set the external feedback pulse dividing
numerator.
−
0 to 2
20
Yes
325
External Feedback
Pulse Dividing
Denominator
Set the external feedback pulse dividing
denominator.
−
1 to 2
20
Yes
326
External
Feedback Pulse
Direction
Switching
Reverse the external feedback pulse count
direction by changing the setting.
−
0 to 1
Yes
0 Count direction not reversed
1 Count direction reversed
327
External
Feedback Pulse
Phase-Z Setting
Set disconnection detection in the Phase-Z
unconnected state when a phase AB output
type external feedback pulse is used.
−
0 to 1
Yes
0 Enabled
1 Disabled
328
Internal/External
Feedback Pulse
Error Counter
Overflow Level
Set the threshold for feedback pulse
deviation errors.
Command
unit
1 to 2
27
Yes
329
Internal/External
Feedback Pulse
Error Counter Reset
Clear to 0 the feedback pulse error value for
each set rotation speed.
Rotation 0 to 100
Yes
Pn number
Parameter
name
Explanation
Default
setting
Unit
Setting
range
Power
supply
OFF to
ON
Setting
Pn number
Parameter
name
Explanation
Default
setting
Unit
Setting
range
Power
supply
OFF to
ON
400
Input Signal
Selection 1
Set the input signal 1 function and logic.
−
0 to
00FFFFFFh
Yes
401
Input Signal
Selection 2
Set the input signal 2 function and logic.
−
0 to
00FFFFFFh
Yes
402
Input Signal
Selection 3
Set the input signal 3 function and logic.
−
0 to
00FFFFFFh
Yes
403
Input Signal
Selection 4
Set the input signal 4 function and logic.
−
0 to
00FFFFFFh
Yes
404
Input Signal
Selection 5
Set the input signal 5 function and logic.
−
0 to
00FFFFFFh
Yes
405
Input Signal
Selection 6
Set the input signal 6 function and logic.
−
0 to
00FFFFFFh
Yes
406
Input Signal
Selection 7
Set the input signal 7 function and logic.
−
0 to
00FFFFFFh
Yes
407
Input Signal
Selection 8
Set the input signal 8 function and logic.
−
0 to
00FFFFFFh
Yes
408
Input Signal
Selection 9
Set the input signal 9 function and logic.
−
0 to
00FFFFFFh
Yes
Setting
Содержание OMNUC G5
Страница 26: ......
Страница 82: ......
Страница 222: ......
Страница 266: ......
Страница 356: ......
Страница 364: ......
Страница 430: ......
Страница 542: ......
Страница 543: ...I OMNUC G5 SERIES AC SERVOMOTOR AND SERVO DRIVE USER S MANUAL Index...
Страница 548: ...Index 5 Index I...
Страница 549: ......