
6
6-25
6-7 Gain Switching Function
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
Applied Functions
Timing by Gain Switching Setting
Switching between Gain 1 (Pn100 to Pn104) and Gain 2 (Pn105 to Pn109) occurs at the
following timings. Take note that, in the case of position loop gains, switching occurs based on
the setting of Pn119.
For the details of each gain, refer to "Chapter 8, Parameters Details".
The details of gain switching setting vary depending on the CONTROL mode used. For the
details of settings available in each mode, refer to "Gain Switching Setting for Each CONTROL
mode" (P.6-29).
GAIN SWITCHING mode = 2: Gain Switching (GSEL)
Instant switching occurs when a gain switching command is issued from the network.
Gain 1
GSEL
Gain 1
Gain 2
Gain switching instruction
Position command
Содержание OMNUC G5
Страница 26: ......
Страница 82: ......
Страница 222: ......
Страница 266: ......
Страница 356: ......
Страница 364: ......
Страница 430: ......
Страница 542: ......
Страница 543: ...I OMNUC G5 SERIES AC SERVOMOTOR AND SERVO DRIVE USER S MANUAL Index...
Страница 548: ...Index 5 Index I...
Страница 549: ......