5-27
5-6 Full Closing Control
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
5
BASIC CONTROL Mode
External Feedback Pulse Type Selection (Pn323, Pn326)
Set the external scale output type and direction.
Parameter
number
Parameter name
Explanation
Setting
range
Unit
Pn323
External
Feedback Pulse
Type Selection
Select the type of the external scale
to be used.
0 to 3
−
Pn326
External
Feedback Pulse
Direction
Switching
If the count directions of the external
scale feedback pulse and the
encoder total feedback pulses do not
match, set the reversal of the
external scale feedback pulse
direction.
0: Not reversed, 1: Reversed
0 to 1
−
Set
value
External scale type
0
90 phase difference output type
1
Serial communications (Incremental
encoder specifications)
2
Serial communications (Absolute
encoder specifications)
Содержание OMNUC G5