8-45
8-5 Interface Monitor Setting Parameters
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
8
Parameters Details
Explanation of Set Values
Do not set it to a value other than a number 0 to 5, and 8 to 10.
Refer to "11-2 Warning List" (P.11-4) for more information on settings.
The set values for this parameter are same as Warning Output Selection 1 (Pn440).
Set the positioning completion range.
The set values for this parameter are same as Positioning Completion Range 1 (Pn431).
Pn439
Brake Release Speed Setting
Setting
range
30 to 3,000
Unit
r/min
Default
setting
Power OFF
and ON
Yes
All
Released (ON)
Released (ON)
Engaged (OFF)
Engaged (OFF)
Motor rotation speed
Pn439 set value
Pn438 set value
When the Pn438
set value is early
Pn438 set value
Motor rotation speed
Pn439 set value
t1
*1
t1
*1
When the timing of
reaching the Pn439
set value or lower is early
Pn440
Warning Output Selection 1
Setting
range
0 to 10
Unit
−
Default
setting
Power OFF
and ON
−
All
Set
value
Explanation
0
No
1
Overload warning
2
Excessive regeneration warning
3
Battery warning
4
Fan warning
5
Encoder communications warning
8
Encoder overheating warning
9
External scale error warning
10
External scale communications error warning
Pn441
Warning Output Selection 2
Setting
range
0 to 7
Unit
−
Default
setting
Power OFF
and ON
−
All
Pn442
Positioning Completion Range 2
Setting
range
0 to 262,144
Unit
Command unit
Default
setting
25
Power OFF
and ON
−
Position
Full closing
Содержание OMNUC G5
Страница 26: ......
Страница 82: ......
Страница 222: ......
Страница 266: ......
Страница 356: ......
Страница 364: ......
Страница 430: ......
Страница 542: ......
Страница 543: ...I OMNUC G5 SERIES AC SERVOMOTOR AND SERVO DRIVE USER S MANUAL Index...
Страница 548: ...Index 5 Index I...
Страница 549: ......