12-25
12-2 Parameter List
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
12
Appe
ndix
507
Stop Selection
with Main
Power Supply
OFF
Set the stop operation when the main power
supply is turned OFF.
The set values for this parameter are the same
as Stop Selection with Servo OFF (Pn506).
−
0 to 9
−
508
Undervoltage
Alarm Selection
Select whether to trip the LV or turn OFF the
servo if there is a main power supply alarm.
−
0 to 1
−
509 Momentary Hold Time Set the main power supply alarm detection time.
1 ms
70 to 2,000
Yes
510
Stop Selection
for Alarm
Generation
Set the alarm sequence.
−
0 to 7
−
0
During deceleration: Dynamic brake
After stopping: Dynamic brake
1
During deceleration: Free-run
After stopping: Dynamic brake
2
During deceleration: Dynamic brake
After stopping: Servo free
3
During deceleration: Free-run
After stopping: Servo free
4
During Immediate stop alarm
deceleration: Immediate stop
During deceleration: Dynamic brake
After stopping: Dynamic brake
5
During Immediate stop alarm
deceleration: Immediate stop
During deceleration: Free-run
After stopping: Dynamic brake
6
During Immediate stop alarm
deceleration: Immediate stop
During deceleration: Free-run
After stopping: Servo free
7
During Immediate stop alarm
deceleration: Immediate stop
During deceleration: Free-run
After stopping: Servo free
511 Immediate Stop Torque Set the torque limit for immediate stops.
%
0 to 500
−
512
Overload Detection
Level Setting
Set the overload detection level.
%
0 to 500
−
513
Overspeed Detection
Level Setting
Set the overspeed error detection level.
r/min
0 to
20,000
−
514
Overrun Limit
Setting
Set the motor over-travel distance for
position commands.
0.1
Rotation
0 to
1,000
−
515
Control Input
Signal Read
Setting
Select from one of 4 values for the IF read cycle.
−
0 to 3
Yes
0 0.166ms
1 0.333 ms
2 1 ms
3 1.666 ms
516
Alarm Reset
Condition
Setting
Set the alarm clear input detection method.
−
0 to 1
−
0 120 ms
1 Follow the Control Input Signal Read Setting (Pn515).
Pn number
Parameter
name
Explanation
Default
setting
Unit
Setting
range
Power
supply
OFF to
ON
Setting
Содержание OMNUC G5
Страница 26: ......
Страница 82: ......
Страница 222: ......
Страница 266: ......
Страница 356: ......
Страница 364: ......
Страница 430: ......
Страница 542: ......
Страница 543: ...I OMNUC G5 SERIES AC SERVOMOTOR AND SERVO DRIVE USER S MANUAL Index...
Страница 548: ...Index 5 Index I...
Страница 549: ......