d-Color MF4003/MF3303
L TROUBLESHOOTING > 3. TROUBLE CODE
L-56
Rank
B
Trouble detection condition
• C9403: At the CIS gain adjustment, the machine detected that the output of the CIS LED is lower than the
specified value.
• C9404: After a scan job is completed, the machine detected that the average output of the CIS LED is greater
than the specified value.
Trouble isolation
Scanner
Relevant electrical parts
• Flat cable
• DF CIS module (DF CIS)
• CPU board (CPUB)
• Base board (BASEB)
Procedure
1.
Check the connector between DF CIS-BASEB CN5 for proper connection and correct as necessary.
2.
Check CPUB for proper installation and correct as necessary.
3.
Replace the flat cable.
4.
Replace the DF CIS module assy.
5.
6.
3.15.3 C9701
Contents
Trouble type
C9701: Front side reading device cable break detection
Rank
A
Trouble detection condition The cable between the CIS module (IR CIS) and the base board (BASEB) is break.
Trouble isolation
Scanner
Relevant electrical parts
• Flat cable
• CIS module (IR CIS)
• CPU board (CPUB)
• Base board (BASEB)
Procedure
1.
Check the connector between IR CIS-BASEB CN6 for proper connection and correct as necessary.
2.
Check CPUB for proper installation and correct as necessary.
3.
Replace the flat cable.
4.
5.
6.
3.15.4 C9702
Contents
Trouble type
C9702: Back side reading device cable break detection
Rank
A
Trouble detection condition The cable between the DF CIS module (DF CIS) and the base board (BASEB) is break.
Trouble isolation
Scanner
Relevant electrical parts
• Flat cable
• DF CIS module (DF CIS)
• CPU board (CPUB)
• Base board (BASEB)
Procedure
1.
Check the connector between DF CIS-BASEB CN5 for proper connection and correct as necessary.
2.
Check CPUB for proper installation and correct as necessary.
3.
Replace the flat cable.
4.
Replace the DF CIS module assy.
5.
6.
3.16 CA###
3.16.1 CA051, CA052, CA053
Contents
Trouble type
• CA051: Standard controller configuration failure
• CA052: Controller hardware error
• CA053: Controller start failure
Rank
C
Trouble detection condition
• CA051: The controller of the CPU board (CPUB) is faulty.
• CA052: A controller hardware error is detected in the network interface.
• CA053: A controller start failure is detected in the controller interface.
Trouble isolation
-
Service Manual
Y119930-3
Содержание d-Color MF 4003
Страница 1: ...Multifunction Digital Copier d Color MF4003 MF3303 Service Manual Version 2 0 Code Y119930 3 ...
Страница 48: ...This page is intentionally left blank ...
Страница 54: ...This page is intentionally left blank ...
Страница 70: ...This page is intentionally left blank ...
Страница 76: ...This page is intentionally left blank ...
Страница 98: ...This page is intentionally left blank ...
Страница 216: ...This page is intentionally left blank ...
Страница 354: ...This page is intentionally left blank ...
Страница 388: ...This page is intentionally left blank ...
Страница 398: ...This page is intentionally left blank ...
Страница 512: ...d Color MF4003 MF3303 L TROUBLESHOOTING 10 DIAGNOSTIC CODES L 114 Not used bit is set to 0 Service Manual Y119930 3 ...
Страница 570: ...This page is intentionally left blank ...
Страница 572: ...This page is intentionally left blank ...
Страница 574: ...This page is intentionally left blank ...
Страница 686: ...This page is intentionally left blank ...
Страница 687: ...UPDATINGSTATUS DATE UPDATED PAGES PAGES CODE 2nd EDITION 688 Y119930 3 07 2019 1st EDITION 650 06 2020 ...