d-Color MF4003/MF3303
I SERVICE MODE > 15. ADF
I-78
15. ADF
15.1 Original Stop Position
• To manually adjust the original stop position and the read position in each of the DF modes.
• When the result is Unable in the automatic adjustment of the original stop position.
Sub Scanning Direction 1-Side
Target
Setting range
Default setting
0.0 ± 2.0 mm
-5.0 to +5.0 mm (1 step: 0.1 mm)
0.0 mm
NOTE
▪ Before performing this adjustment, the “
“ adjustment needs to be complete.
<Procedure>
1.
Place the chart in the document feed tray.
• DF reading chart (for Duplex): with the front side facing up.
2.
Make a full size copy of the chart.
3.
Check that the difference in the widths of B between the chart and the copy sample falls within the target.
B
4.
Touch [Sub Scanning Direction 1-Side].
5.
Enter the value from the 10-key pad. (Press the [+/-] key to change the +/- code.)
• If the difference in the widths of B is greater than the target, enter the [+] value.
• If the difference in the widths of B is smaller than the target, enter the [-] value.
6.
Make a copy of the chart again.
7.
Check the difference in the width B between the chart and the discharged copy sample.
8.
If width B is outside the target, change the setting again and make a check again.
9.
If width B falls within the target, touch [END].
Sub Scanning Direction 2-Side
Target
Setting range
Default setting
0.0 ± 2.0 mm
-5.0 to +5.0 mm (1 step: 0.1 mm)
0.0 mm
NOTE
▪ Before performing this adjustment, the “
” adjustment and the “
” adjustment need to be complete.
<Procedure>
1.
Place the chart in the document feed tray.
• DF reading chart (for Duplex): with the front side facing up.
2.
Make a full size copy of the chart.
3.
Check that the difference in the widths of B between the chart and the copy sample falls within the target.
B
4.
Touch [Sub Scanning Direction 2-Side].
5.
Enter the value from the 10-key pad. (Press the [+/-] key to change the +/- code.)
• If the difference in the widths of B is greater than the target, enter the [+] value.
• If the difference in the widths of B is smaller than the target, enter the [-] value.
6.
Make a copy of the chart again.
7.
Check the difference in the width B between the chart and the discharged copy sample.
8.
If width B is outside the target, change the setting again and make a check again.
9.
If width B falls within the target, touch [END].
Main Scanning (Front)
Target
Setting range
Default setting
0.0 ± 2.0 mm
-1.7 to +1.7 mm (1 step: 0.1 mm)
0.0 mm
<Procedure>
1.
Place the chart in the document feed tray.
• DF reading chart (for Duplex): with the front side facing up.
2.
Make a full size copy of the chart.
3.
The difference in the widths of A between the chart and the copy sample should fall within the following target.
Service Manual
Y119930-3
Содержание d-Color MF 4003
Страница 1: ...Multifunction Digital Copier d Color MF4003 MF3303 Service Manual Version 2 0 Code Y119930 3 ...
Страница 48: ...This page is intentionally left blank ...
Страница 54: ...This page is intentionally left blank ...
Страница 70: ...This page is intentionally left blank ...
Страница 76: ...This page is intentionally left blank ...
Страница 98: ...This page is intentionally left blank ...
Страница 216: ...This page is intentionally left blank ...
Страница 354: ...This page is intentionally left blank ...
Страница 388: ...This page is intentionally left blank ...
Страница 398: ...This page is intentionally left blank ...
Страница 512: ...d Color MF4003 MF3303 L TROUBLESHOOTING 10 DIAGNOSTIC CODES L 114 Not used bit is set to 0 Service Manual Y119930 3 ...
Страница 570: ...This page is intentionally left blank ...
Страница 572: ...This page is intentionally left blank ...
Страница 574: ...This page is intentionally left blank ...
Страница 686: ...This page is intentionally left blank ...
Страница 687: ...UPDATINGSTATUS DATE UPDATED PAGES PAGES CODE 2nd EDITION 688 Y119930 3 07 2019 1st EDITION 650 06 2020 ...