7.2.23 Timer Value Setting
Code
Command
Symbol
Data Range
Data Length
(byte)
16
h
Timer value setting
TM
1
~
2,147,483,647
4
“TM” is the parameter setting the time that a timer is up. The unit of the setting value is
μsec.
Timer Value = TM [
μsec]
The current timer value during the timer operation can be read by current timer value reading command (38h).
7.2.24 Split Pulse Setting 1
Code
Command
Symbol
Data Range
Data Length
(byte)
17
h
Split pulse setting 1
SP1
WR6
Split length
:
2
~
65,535
4
WR7
Pulse width
:
1
~
65,534
“SP1” is the parameter setting a split length and pulse width of a split pulse.
The unit of split length and pulse width is drive pulse. Set a split length to WR6 and pulse width to WR7.
Split length and pulse width can be altered during output of split pulse. When split length and pulse width are newly set, output of
split pulse will continue at the new settings.
This data length is 4 bytes, so even if only one of split length and pulse width is altered, the appropriate data should be set in both
WR6 and WR7 registers.
The value of split pulse setting 1 (SP1) can be read by split pulse setting 1 reading command (47h).
7.2.25 Split Pulse Setting 2
Code
Command
Symbol
Data Range
Data Length
(byte)
18
h
Split pulse setting 2
SP2
Split pulse number
:
0
,
1
~
65,535
2
“SP2” is the parameter setting the split pulse number to output. When the split pulse number is set to 0, it continues to output split
pulses until the output of split pulse is stopped by a command or synchronous action.
The split pulse number can be altered during output of split pulse.
This data length is 2 bytes, the setting data should be written in WR6 register.