NOVA electronics Inc. MCX514 -
180
-
180
-
6.11
Main Status Register: RR0
Main status register is used for displaying the driving and error status of each axis. It also displays ready signal for continuous
interpolation, quadrant of circular interpolation and continuous interpolation pre-buffer stack counter (SC).
X-DRV
D7
D6
D5
D4
H
L
D15
D14
D13
D12
D11
D10
D9
D8
D3
D2
D1
D0
RR0
Y-DRV
Z-DRV
U-DRV
X-ERR
Y-ERR
Z-ERR
U-ERR
ZONE0
ZONE1
ZONE2
CNEXT
HSTC0
HSTC1
HSTC2
HSTC3
D3
~
0 n-DRV
Displaying driving status of each axis.
When the bit is 1, the axis is outputting drive pulses, and when
the bit is 0, the driving of the axis is finished. During execution of automatic home search or helical
calculation, this bit is set to 1.
Once the in-position input signal nINPOS for servomotor is active, nINPOS will return to 0 after
the drive pulse output is finished.
D7
~
4 n-ERR
Displaying error status of each axis.
If any of the error bits (D7
~
D0) of each axis RR2 register becomes 1, this bit will become 1. When an error
occurs in any axis of sub chip during multichip interpolation, the error bit of main axis in main chip will
become 1.
During driving except interpolation driving (including automatic home search), this bit will return to 0 by
the error/finishing status clear command (79h) or the start of next driving. When interpolation driving is
performed, be sure to clear the error by the error/finishing status clear command (79h). Otherwise,
interpolation driving will not work properly after that.
D10
~
8 ZONEm
Displaying the quadrant of the current position in circular interpolation.
D10
D9
D8
Q
uadrant
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
0
1
2
3
4
5
6
7
D11 CNEXT
Displaying the writable state of next data for continuous interpolation.
When interpolation driving is started, the bit is set to 1 during the period from 1 to 7 of pre-buffer stack
counter, and it is possible to write interpolation data for next node (parameters and interpolation
commands).
D15
~
12 HSTC3
~
0
Displaying the value of continuous interpolation pre-buffer stack counter (SC).
D15
D14
D13
D12
Stack Counter (SC)
0
0
0
0
0
0
0
0
1
0
0
0
0
1
1
1
1
0
0
0
1
1
0
0
1
1
0
0
1
0
1
0
1
0
1
0
0
1
2
3
4
5
6
7
8